Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202555488 - Press Operator Crushes Both Hands When Equipment Cycles

Accident Summary Nr: 202555488 -- Report ID: 0950631 -- Event Date: 11/06/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31553159011/13/20123363331521Dynacast Inc

Abstract: At approximately 4:30 p.m. on November 6, 2012, Employee #1, a 22-year-old male Pressing Machine Operators with Dynacast Inc., was employed as a temporary machine operator assigned to the production floor. Employee #1 was operating a punch press also known as trim press at the work station identified as T-21. When he reached into the point of operation in an attempt to retreat work pieces the machine cycled and crushed both of his hands between the dies. Employee #1 was hospitalized for fracture injures to his hands as a result of the event. Employee #1 was a contract employee from a staffing agency at the time of his injury.

Keywords: DIE, FINGER, LOCKOUT, CRUSHED, POINT OF OPERATION, PRESS OPERATOR, HAND, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315531590 Hospitalized injury Fracture Pressing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close