Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 202521753 - Employee Fractures Hip After Slipping And Falling

Accident: 202521753 -- Report ID: 0950624 -- Event Date: 10/13/2011
InspectionOpen DateSICEstablishment Name
31499437711/09/20115411Save Mart Supermarkets #371
At approximately 10:45 on October 13, 2011, Employee #1, a bakery clerk, was placing a box of sliced bread on top of a rack in the freezer. She slipped and fell, landing on her right hip, and fracturing it. She was hospitalized for treatment.
Keywords: fracture, slip, bakery rack, fall, freezer compartment, hip, work surface
Employee # Inspection Age Sex Degree Nature Occupation
1 314994377 Hospitalized injury Fracture Bakers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close