Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 202472130 - Employee Is Killed When Legs Are Caught In Moving Conveyor

Accident: 202472130 -- Report ID: 0420600 -- Event Date: 07/14/2007
InspectionOpen DateSICEstablishment Name
31133235707/16/20074931Action Labor Of Florida, Llc
At approximately 7:30 p.m. on July 14, 2007, Employees #1 and a coworker, both ash cleanup laborers, were instructed to shovel fly ash into a conveyer inspection hatch. A chain driven conveyer was used to transport fly ash, which was a byproduct of solid waste incineration. The fly ash previously backed up out of the inspection hatch and onto the floor adjacent to the conveyer, due to a motor failure in hoppers Number 1 and Number 2, which were attached to the conveyer system. Employee #1 and the coworker were shoveling, while the conveyer was operating. The top of the conveyer at the site of the accident was approximately 29 in. off the ground. The conveyer was square and its depth was 21.5 in. The overall width of the conveyer was 59.5 in. The inspection hatch opening was 18 in. by 32.5 in. The conveyor was custom designed by the Ashtech Corporation of Ohio. Employee #1 and the coworker were shoveling fly ash into the inspection hatch opening, when the coworker walked approximately five ft to the adjacent outer wall of a stairwell and leaned his shovel against it, as he was contemplating wetting the fly ash down and using a wheel barrow or bobcat to haul it away. At that time, the coworker had his back turned to Employee #1, when he heard Employee #1's scream. The coworker turned around and found Employee #1 standing in the inspection hatch opening with his legs pinched between the inspection hatch edge and the moving conveyer flight. The coworker attempted to pull Employee #1 from the inspection hatch but with no success. Subsequently, the coworker ran to his shift supervisor for help, and the supervisor radioed the control room to shut the conveyer off at approximately 7:50 p.m. Employee #1 had both legs amputated at the knee level and trauma to the upper body. Emergency services were called, and Employee #1 was pronounced dead at the scene. The coworker believed Employee #1 was trying to cross the conveyer to shovel the fly ash on the other side. There was a lack of safety training, machine guarding, and lock out tag out procedures.
Keywords: amputated, guard, hatch, ash, cleaning, lockout, caught between, conveyor, shovel, leg
Employee # Inspection Age Sex Degree Nature Occupation
1 311332357 Fatality Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.