Accident Summary Nr: 202471421 - Two Employees Injured in Fire and Explosion

Accident Summary Nr: 202471421 -- Report ID: 0950643 -- Event Date: 11/30/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31482775901/09/20122844325611Shadow Holdings Llc Dba Bocchi Laboratories

Abstract: At approximately 8:05 p.m. on November 30, 2011, Employee #1 was cleaning and drying a stainless steel tank, using hot water and ethanol. Employee #1 also hooked up a compressed air hose at the bottom of the tank to dry the tank quicker. At the same time, Employee #2 was heating a solid product in a drum with a torch so it could be poured into a tank, approximately 15 ft from tank. The lid of the tank was opened, and ethanol vapors filled the area. An explosion and fire occurred and both Employee #1 and Employee #2 were seriously burned. Both Employee #1 and Employee #2 were hospitalized for their injuries.

Keywords: BURN, DRUM, FIRE, HOSE, TORCH, EXPLOSION, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 314827759 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 314827759 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close