Accident Summary Nr: 202466900 - Employee dies after drum explosion with flammable residue to

Accident Summary Nr: 202466900 -- Report ID: 0950643 -- Event Date: 11/04/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31242992111/04/20083479332812Advanced Powder Coating & Sandblasting

Abstract: On November 03, 2008 an employee was fatally injured at Advanced Powder Coating & Sandblasting in Paso Robles. Employee #1 had been working as a sandblaster for over four years. On the day of the accident, Employee #1 was opening a used drum with flammable residue with a torch. Employee #2, a supervisor, requested Employee #1 to discontinue the use of the torch. This did not take place and Employee #1 continued his cutting efforts, leading to the drum exploding and killing him. The employer was issued two general citations for lack of training and using a torch on a drum with flammable residue.

Keywords: FLAMMABLE LIQUID, DRUM, TORCH, EXPLOSION, INEXPERIENCE, SANDBLASTING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 312429921 Fatality Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close