Accident Report Detail
Accident: 202344008 - Employee Struck By Trowel
Accident: 202344008 -- Report ID: 0352430 -- Event Date: 10/13/2003 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
307104851 | 10/13/2003 | 1771 | T.L. Sexton Company, Inc. | ||||
On October 13, 2003, Employee #1 was assigned to finish the concrete slab that had been poured for the garage area of a single-family home. Employee #1 was operating a 46 in. walk behind powered concrete trowel when he went to cut the trowel off so he could switch take it to another work areas. Employee #1 thought that he cut the machine off so he let go of the trowel and started to walk away. The trowel swung around and struck Employee #1 in the left side around the bottom of his ribs. Employee #1 grabbed the trowel and cut it off. After having trouble breathing, Employee #1 walked to a stack of plywood next to the foundation and tried to call emergency personnel. Employee #1 was hospitalized and treated for his injuries. | |||||||
Keywords:
concrete slab, machine operator, construction, rib, struck by
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Single family or duplex dwelling | New project or new addition | $250,000 to $500,000 | 3 | 8 | |||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 307104851 | Hospitalized injury | Other | Concrete and terrazzo finishers | FallDist: FallHt: Cause: Pouring concrete floor at grade FatCause: Struck by falling object/projectile |