Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 202340022 - Employee Asphyxiated By Nitrogen Gas

Accident: 202340022 -- Report ID: 0215000 -- Event Date: 09/20/2001
InspectionOpen DateSICEstablishment Name
30294588603/08/20013845Magnex Scientific Limited
On September 20, 2001, Employee #1 was installing an MRI machine. During installation Employee #1 was using liquid nitrogen to cool the magnet. The nitrogen was not properly ventilated and displaced the oxygen in the room. Employee #1 died of asphyxiation.
Keywords: magnet, oxygen, asphyxiated, ventilation, gas, nitrogen
Employee # Inspection Age Sex Degree Nature Occupation
1 302945886 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close