Accident Report Detail
Accident Summary Nr: 202313946 - Employee is impaled by baler processor machine
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 119691806 | 11/24/2003 | 4953 | 562213 | Monterey City Disposal Service, Inc |
Abstract: At approximately 9:30 a.m. on August 29, 2003, Employee #1 was attempting to un-jam a baler and compactor processor machine. He was actually inside of machine, which did not have a lockout and tag-out program. Nor did it have any other form de-energizing protocol in place. The ambient noise of the immediate work area drowned out any verbal communication, so hand signals were developed for communication, and were replied upon. At certain point, Employee #1 hand signaled to turn the machine off, and then bent further into machinery to perform his task. The hand signal was misread, and the area supervisor, pushed the "on" button. Employee #1 was impaled by the hydraulic cylinder through his chest wall. He was hospitalized and treated for his injures.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119691806 | Hospitalized injury | Puncture | Graders and sorters, except agricultural |
Translate