Accident Report Detail
Accident Summary Nr: 202311486 - Employee injured when caught by power roller
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 304443088 | 04/20/2001 | 1623 | 0 | Metro Sewer Services, Inc. |
Abstract: This company does maintenance and rehabilitation of underground pipelines. One process used involves the placement of a "cured-in-place" lining on the inside of existing sewer lines. This involves inserting an inverted resin-impregnated felt tube from one manhole location to the next manhole. Through a process which circulates hot water through the inverted liner, a sufficient temperature is reached and maintained which hardens the resin to a fiberglass-like material. When the liner hardens, the excess hardened liner is removed and the hose is retracted. This process takes from 6 to 8 hours for 300 to 400 feet of liner. During one such liner installation, Employee #1 was caught by the powered roller which is used to insert and remove the lay-flat hose, and pulled around the roller, receiving injuries to his arm and legs. Employee #1 was hospitalized with a fracture.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Pipeline | Alteration or rehabilitation | $50,000 to $250,000 | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 304443088 | Hospitalized injury | Fracture | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Installing underground plumbing conduit Fatality Cause: Other |