Accident: 202087649 - Employee Amputates Fingers And Crushes Wrist In Power Press

Accident: 202087649 -- Report ID: 0524700 -- Event Date: 03/29/2006
InspectionOpen DateSICEstablishment Name
30944226705/08/20063069Ashland Rubber Mat Co. Inc.
At approximately 5:00 a.m. on March 29, 2006, Employee #1 was employed by the Ashland Rubber Mat Company, Inc. The company, in business since 1936, recycles used tires into dock bumpers and floor mats. She was operating a Walsh Model 65-X full revolution mechanical power press, with Serial Number 10792, to punch out dock bumpers from a section of a recycled rubber tire. This press has a 4-inch stroke and can exert a force of 65 tons. The operation required that Employee #1 move the tire half its radius through the die for the pieces to be punched out. As she worked, the press made an uncommanded stroke, severing the first and second digits (index and middle fingers) on her right hand and crushing her right wrist. Her foot was not in contact with the pedal. She was hospitalized. An investigation revealed that the company had in operation a number of mechanical power presses, some dating back to the 1930s, which had not been updated with required safety features. The press on which Employee #1 sustained her injury was not equipped with effective guarding. Although a wire mesh barrier guard was installed, operators could reach around and over the guard into the press's point of operation. The guard did not comply with table O-10 of section 1910.217 of the OSHA regulations, and it was easily removable by the operator. Prior to the accident, the company had allowed the operation of some presses that lacked guarding on the foot pedals and had barrier guards that did not comply with table O-10. Employee #1 was not trained in safe work methods when using a mechanical power press.
Keywords: die, amputated, finger, caught between, crushed, die guard, press operator, untrained, press, unguarded
Employee # Inspection Age Sex Degree Nature Occupation
1 309442267 Hospitalized injury Amputation Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close