Accident Report Detail
Accident Summary Nr: 202081055 - Employee Sustains Electrical Burns
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 315685073 | 07/01/2011 | 1799 | 238990 | Rite Lite Signs, Inc. |
Abstract: On July 1, 2011, Employee # 1 and a coworker were installing signs from the ground using a boom truck to lift and position the signs. Employee #2 was using the controls at the back of the truck to extend the boom and it contacted an overhead power line (13.8 kV). Employee #1 received second and third degree burns to 75 percent of his body.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Commercial building | Alteration or rehabilitation | Under $50,000 | 1 | 35 | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 315685073 | Hospitalized injury | Electric Shock | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fencing, installing lights, signs, etc. Fatality Cause: Electric shock, other and unknown cause |