Accident Summary Nr: 201981362 - Employee Struck And Killed By Crane Load Block

Accident Summary Nr: 201981362 -- Report ID: 0950411 -- Event Date: 03/18/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30144017803/18/199916230Wat Irr Incorporated

Abstract: Employee #1 was in the process of repositioning a wire-rope sling around a 24-in. ductile-iron pipe. Employee #1 was struck in the head by the load block of an RD TC-120-6, 10-ton truck-mounted crane that was being used to transport the pipe on the construction site. Employee #1 was transported to the hospital where he treated for an amputated left hand and massive head trauma. Employee #1 died in the hospital from his injuries on the day of the accident.

Keywords: HEAD, RIGGING, AMPUTATED, WIRE ROPE, CONSTRUCTION, PIPE, STRUCK BY, SLING, CRANE BLOCK, HAND
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator New project or new addition $50,000 to $250,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 301440178 Fatality Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.