Accident Report Detail
Accident Summary Nr: 201954500 - One Employee Is Injured, One Later Dies from Toxic Release
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 309702538 | 02/15/2006 | 2869 | 325199 | Rohm And Haas Chemicals, Llc |
Abstract: At approximately 9:00 a.m. on February 15, 2006, Employee #1 and Employee #2 were unclogging a plugged steam ejector and became unconscious. Apparently, an organo-sulphur compound decomposed, liberating hydrogen sulfide and carbon monoxide when it became exposed to temperatures in the vicinity of 160-degrees Celsius. No local monitoring for hydrogen sulfide, carbon monoxide, oxygen or LEL was performed prior to the start of the maintenance. Employee #1 passed out shortly after the line was broken by the removal of a flange. Employee #2 contacted the Emergency Response Team indicating that it appeared Employee #1 was experiencing a heart attack. Employee #2 began to lift up and move Employee #1, but he, too passed out. Emergency Response Team members arrived. CPR was performed. Both were rushed to the hospital. Employee #2 gradually recovered and was released from the hospital on February 19, 2006. Employee #1 never came out of his coma and died on February 18, 2006.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309702538 | Fatality | Asphyxia | Painters, construction and maintenance | ||
| 2 | 309702538 | Hospitalized injury | Asphyxia | Painters, construction and maintenance |
Translate