Accident Report Detail
Accident Summary Nr: 201794658 - Employee's finger is amputated in punch press
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 119821510 | 09/07/2001 | 3589 | 0 | Wilbur Curtis Company |
Abstract: On October 9, 2000, Employee #1 was operating a full-revolution type power operated press, a Ravine EDE100-1450-650 Punch Press, and sustained an amputation of the left index finger tip which involved a loss of bone. The employer claims the machine was being operated in the continuous stroke mode and that it was against company policy, although the company did not have a well established safety training program. Employee #1 states that he was operating the machine in the single stroke mode and that the press double cycled and that the accident occurred due to a faulty machine that had a history of operational problems. The employer did remove the machine from service. There was inadequate guarding of the dies to prevent the operator's fingers from contacting the dies during the normal course of work. Employee #1 was hospitalized.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119821510 | Hospitalized injury | Amputation | Punching and stamping press machine operators |
Translate