Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201790805 - Employee Falls Between Floors

Accident: 201790805 -- Report ID: 0950612 -- Event Date: 08/29/1998
InspectionOpen DateSICEstablishment Name
12555634009/08/19981751L J R Construction Co
Employee #1 was working with another employee to replace temporary decking with permanent decking. As Employee #1 stepped onto 4 ft by eight ft plywood panel (lying over joists to retrieved material), the panel gave way causing Employee #1 to fall through the opening to plywood floor. He fell approximately 9 ft.
Keywords: decking, panel, fall, temporary floor
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Multi-family dwelling New project or new addition $250,000 to $500,000 3
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 125556340 Hospitalized injury Fracture Construction laborers FallDist:
FallHt:9
Cause: Interior carpentry
FatCause: Fall through opening (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.