31627750802/03/20123547V & M Tube Alloy
On February 1, 2012, Employee #1 was repairing a limit switch on a hydro-tester that was used to test pipe for defects. The outlet conveyor that transported the pipe to the table was not locked out. When the hydro-tester operator discharged a pipe onto the conveyor, the pipe struck Employee #1's head. He died two days later. The maintenance supervisor authorized the work on the limit switch while it was energized. According to another worker, Employee #1 was under pressure from the plant manager to get the machine running.
Keywords: fracture, head, repair, lockout, test equipment, skull, conveyor, pipe, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 316277508 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.