Accident Report Detail
Accident: 201693611 - Employee Injured In Tilt Machine Accident
Accident: 201693611 -- Report ID: 0950662 -- Event Date: 07/22/2010 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
312317928 | 07/27/2010 | 3365 | Alcast Foundry Inc | ||||
At approximately 10:30 a.m. on July 22, 2010, Employee #1 and a coworker, were working on a Tilt Pour Machine when the coworker was called to another area. Another coworker came to assist Employee #1 with the pouring operations. Employee #1 and the second coworker continued operating the tilt machine. The coworker was operating the controls and Employee #1 was standing on the other side of the tilt machine. Employee #1 bent down to pick up the tongs and placed his right hand on the Tilt Pour machine. The coworker did not see Employee #1 and started the cycle causing the press to close. Employee #1's right hand became caught, crushing his right index finger and right thumb. | |||||||
Keywords:
fracture, amputated, finger, crushed, struck by
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 312317928 | Hospitalized injury | Amputation | Occupation not reported |