Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201632874 - Two Employees Killed after Water Storage Tank Exploded

Accident Summary Nr: 201632874 -- Report ID: 1054112 -- Event Date: 07/08/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30555601107/08/20028731541710H2o Technologies Ltd

Abstract: On July 8, 2002, Employee #1, a chemist, while experimenting with a system designed to add oxygen to water and using an 80-gallon water storage tank as a reservoir to hold water for the process began generating oxygen, hydrogen gas produced and accumulated in the storage tank. When Employee #1 removed the plug from the top of the 80-gallon water storage tank, the tank exploded. Employee #1 and another electrical engineer employee that was standing nearby died.

Keywords: STORAGE TANK, EXPLOSION, CHEMICAL REACTION, WATER TANK, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 305556011 Fatality Other Occupation not reported
2 305556011 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.