Accident: 201632247 - Employee Pinned Between Wall And Sotrm Drain Inlet Box

Accident: 201632247 -- Report ID: 1054112 -- Event Date: 11/19/2001
InspectionOpen DateSICEstablishment Name
30494774011/21/20011794Northwest Earthmovers Inc
Employee #1 was guiding a storm drain inlet box into an excavation suspended from a track-hoe. One of the manhole picker inserts slipped out of the picking hole onto the concrete box. This caused the box to fall onto the Employee #1, pinning him between the excavation wall and the box. He was hospitalized for his injuries.
Keywords: excavation, pinned, trench, manhole
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street New project or new addition $50,000 to $250,000
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 304947740 Hospitalized injury Fracture Occupation not reported FallDist:
FallHt:
Cause: Installing culverts and incidental drainage
FatCause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.