Accident: 201570504 - Employee Killed In Fall Into Elevator Pit

Accident: 201570504 -- Report ID: 0830500 -- Event Date: 05/12/1999
InspectionOpen DateSICEstablishment Name
30276452705/13/19991799High Plains Builders Inc.
A two man crew of millwrights was replacing a belt on an elevator leg. The leg ran into a pit just over 25-feet deep. They had replaced the belt and were in the process of adjusting the belt. The adjustment was done in the bottom of the pit. The crew had removed a cover from an access or hoist hole to lower tools and materials and to supply light to the bottom of the pit area. The cover had been partly replaced, but it was not supported at one corner. Employee #1 was crossing the area to show a coworker, who witnessed the accident, where the alignment marks were located on the leg. Employee #1 stepped on the cover and fell to his death.
Keywords: cover, repair, laceration, pit, fall, elevator shaft
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Tower, tank, storage elevator Maintenance or repair $50,000 to $250,000 80 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 302764527 Fatality Other Millwrights FallDist:
FallHt:25
Cause: Elevator, escalator installation
FatCause: Fall through opening (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.