Accident Report Detail
Accident Summary Nr: 201562279 - Employee Is Struck and Killed by Debris from Burst Tank
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 312408743 | 04/28/2009 | 4212 | 484220 | D&A Mcrae Inc |
Abstract: On April 27, 2009, Employee #1 was working at a truck maintenance facility. The facility had installed an above ground atmospheric storage tanks for used motor oil piped out from the maintenance bay. The tanks were in a concrete confinement area placed below surface level. During the initial use of the tanks, employees noticed a leak coming from the first 500 gallon tank in the chain. Employee #1 clamped the drain valve and emplaced a catch pan under the valve of the first tank. A coworker attempted to empty the tank by the use of compressed air. The tank was closed without venting. The tank end where the Employee #1 worked burst, striking him on the head and pinning his head against a concrete wall. He died from blunt force trauma.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312408743 | Fatality | Concussion | Machinery maintenance occupations |