Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201523461 - Employee Injures Legs In Fall From Loading Dock

Accident: 201523461 -- Report ID: 0111500 -- Event Date: 03/25/2010
InspectionOpen DateSICEstablishment Name
31416530903/25/20102731Trudy Corporation
On March 25, 2010, Employee #1 fell 4 ft 5 in. to the ground from a malfunctioning manually operated metal loading dock. Immediately following the fall of Employee #1, a 3 yard metal dumpster filled with cardboard fell off the dock and on to the legs of Employee #1. Employee #1 sustained fractures to his left shin and heel and his right ankle. Employee #1 was hospitalized.
Keywords: fracture, dumpster, fall, falling object, loading dock, mech malfunction, ankle, foot, leg
Employee # Inspection Age Sex Degree Nature Occupation
1 314165309 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close