Accident: 201505252 - Three Employees Injured Entering Fermentation Tank

Accident: 201505252 -- Report ID: 0950614 -- Event Date: 09/03/2004
InspectionOpen DateSICEstablishment Name
30733481309/03/20042085Takara Sake Usa Inc.
At approximately 8:30 a.m. on September 3, 2004, Employee #1, a subcontractor, entered a fermentation tank to remove a foreign substance. The tank contained a hazardous substance and Employee #1 collapsed. Employees #2 and #3, who worked for the host employer entered the space to rescue Employee #1, but were also overcome by the toxic atmosphere. All three employees were rescued by coworkers who ventilated the tank and entered to retrieve them. Employees #1, #2, and #3 were transported to Alta Bates Medical Center in Berkley, CA where they were treated and discharged. The employees were issued citations for violation of T8CCR section 5157.
Keywords: asphyxiated, ventilation, collapse, confined space, work rules, toxic atmosphere, intoxicated, chemical vapor, tank
Employee # Inspection Age Sex Degree Nature Occupation
1 307334813 Hospitalized injury Asphyxia Miscellaneous plant and system operators
2 307334813 Hospitalized injury Asphyxia Miscellaneous plant and system operators
3 307334813 Hospitalized injury Asphyxia Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.