Accident Report Detail

Accident: 201407145 - Fall Protection Anchorage Point Fails And Employee Is Killed

Accident: 201407145 -- Report ID: 0552651 -- Event Date: 05/05/2004
InspectionOpen DateSICEstablishment Name
12705771905/05/20041721Morris Painting
On May 5, 2004, an employee fell from a communication tower after attaching fall protection to a faulty anchorage point. He fell approximately 18 feet and was killed.
Keywords: anchor, maintenance, communication tower, construction, equipment failure, fall, fall protection, tie-off, tower
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Tower, tank, storage elevator Maintenance or repair $50,000 to $250,000 90 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 127057719 Fatality Fracture Construction laborers FallDist:
FallHt:90
Cause: Exterior painting
FatCause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.