Accident: 201363660 - Truck Driver Is Electrocuted By Power Line

Accident: 201363660 -- Report ID: 0419400 -- Event Date: 04/05/2011
InspectionOpen DateSICEstablishment Name
31530240604/08/20114212Resourceful Environmental Services, Inc.
On April 4, 2011, a truck driver was loading a 20 yard dumpster onto the back of a truck. The driver was standing on the side of the truck operating levers to extend a tarp to cover the dumpster and the tarping arm came in contact with the overhead power line. The section of the tarping arm on the passenger side of the truck contacted a 7,800 volt power line, electrocuting the driver.
Keywords: insulator, electrocuted, dumpster, truck, arm
Employee # Inspection Age Sex Degree Nature Occupation
1 315302406 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.