Accident Summary Nr: 201361094 - Employee killed in carbon dioxide tank explosion
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 302395785 | 03/10/2000 | 5093 | 0 | Morris Brothers Metals Inc |
Abstract: Employee #1 was working at a shaker table sorting waste metal from compressed bales of recyclable metals when the shear cut into a compressed carbon dioxide tank, resulting in an explosion. Pieces of shrapnel generated in the explosion struck and killed Employee #1. The company had two signs at various locations before entering the plant, stating that they do not accept any type of compressed gas cylinders or other contraband before they are processed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 302395785 | Fatality | Puncture | Occupation not reported |