Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 201360435 - Employee Breaks Leg, Dies From Blood Clot

Accident: 201360435 -- Report ID: 0419400 -- Event Date: 12/04/1997
InspectionOpen DateSICEstablishment Name
30103395712/09/19971382Well Data Services
Employee #1 was walking across the wood decking lying on the ground leading to the stairs. He slipped and fell, breaking his leg. Employee #1 later died due to a blood clot that formed in his broken leg.
Keywords: blood clot, fracture, stair, gas well, slip, walking surface, leg
Employee # Inspection Age Sex Degree Nature Occupation
1 301033957 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close