Accident Report Detail
Accident Summary Nr: 201260031 - Employee dies of asphyxia in manhole
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300947256 | 08/19/1996 | 1629 | 0 | Kenny Construction Company |
Abstract: Employee #1, a laborer, and his foreman arrived at a manhole to open a mechanical valve at the bottom of the manhole. While Employee #1 was removing the manhole cover, the foreman was 5 ft away at his truck getting the air tester. When the foreman turned around to go back to the manhole, he saw the top of Employee #1's head disappear into it. The foreman then looked down into the manhole and saw that Employee #1 was unconscious. The foreman tested the air in the manhole and obtained a reading of 14% oxygen. He immediately called 911, and Employee #1's body was retrieved by the local fire department with the use of SCBAs. OSHA's testing of the manhole showed oxygen levels of between 12 and 14 percent. Tests for carbon monoxide, hydrogen sulfide, and flammable vapors were negative. Tests for carbon dioxide were positive, with a reading of 35,000 ppm.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300947256 | Fatality | Asphyxia | Construction laborers |
Translate