Accident: 201062593 - Three Employees Injured When Vapors Ignited

Accident: 201062593 -- Report ID: 0950632 -- Event Date: 06/08/1999
InspectionOpen DateSICEstablishment Name
12599939106/09/19991752Amerifloor Technical
Three employees of a polymeric floor coating application contractor were seriously burned while using an electric floor buffer. The employees were using a methyl ethyl ketone solvent to strip an uncured floor when the vapors from the solvent ignited from a spark from the floor buffer. All three employees were working inside a small bathroom, approximately 1,000 cubic ft, when the fire occurred. Employee #1 was operating a floor buffer with brush attachment. The buffer was a Waxie Model 17, a 17-in. electric floor buffer with a 1-horse power, 120-volt electrical motor. The motor was an induction motor, but started with a centrifugal switch that is capable of sparking. Employee #1 was operating the floor buffer, while Employee #2 and Employee #3 poured the solvent onto the floor and then wiped behind the buffer with rags. Employee #1 suffered severe second-and-third-degree burns to 20 percent of his body. Employees #2 and #3 suffered similar injuries over a smaller percent of their body. The accident occurred at a customer's premises, during working hours. The fire caused significant damage to the bathroom, detaching a locked door and separating it from the door frame. The three employees were wearing half-mask respirators with an inappropriate cartridge, short-sleeve shirts, latex exam gloves and the only source of ventilation was from a ceiling fan rated at 6 to 9 air changes per hour. The employer had no safety plan for performing the floor stripping operation and did not bring portable ventilation to the site. When the employee's eyes became irritated, they donned swimming goggles purchased from a sporting goods store in the vicinity and continued to work until the fire occurred.
Keywords: burn, mek, vapor, ventilation, ppe, fire, spark
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Manufacturing plant Alteration or rehabilitation Under $50,000 1
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 125999391 Hospitalized injury Burn/Scald(Heat) Construction trades, n.e.c. FallDist:
FallHt:
Cause: Interior painting and decorating
FatCause: Fire/explosion
2 125999391 Hospitalized injury Burn/Scald(Heat) Construction trades, n.e.c. FallDist:
FallHt:
Cause: Interior painting and decorating
FatCause: Fire/explosion
3 125999391 Hospitalized injury Burn/Scald(Heat) Construction trades, n.e.c. FallDist:
FallHt:
Cause: Interior painting and decorating
FatCause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.