Accident Report Detail
Accident Summary Nr: 201032141 - Employee fractures foot in fall with manbasket
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300757424 | 05/29/1999 | 1542 | 0 | Dome Systems Inc |
Abstract: At approximately 10:15 p.m. on May 28, 1999, Employee #1, four other iron workers, and a crane operator were installing rebar inside a hemispherical dome under construction at a marine terminal for storage of petroleum coke. The iron workers were in a personnel basket that was directly pinned to the 35 ft fixed jib (2 degree offset) of a 65-ton Grove crane, model RT865B, serial #82747. The basket was approximately 64 ft above the floor of the structure when the crane tipped over and the basket fell to the floor. At some during the fall, the basket struck the gunite previously installed on the lower circumferential rings of the wall. This slowed down the basket and the workers during the last part of their fall. Employee #1 suffered a fractured foot and remained hospitalized for over 24 hours. The total weight of the five workers, the rebar to be installed, and the 56 ft long basket was 5,100 lb. This far exceeded the 1,179 lb capacity of the crane, as specified in the crane's load chart.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Tower, tank, storage elevator | New project or new addition | $500,000 to $1,000,000 | 126 | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 300757424 | Hospitalized injury | Fracture | Structural metal workers | Distance of Fall: feet Worker Height Above Ground/Floor: 64 feet Cause: Emplacing reinforcing steel Fatality Cause: Fall from/with bucket (aerial lift/basket) |
Translate