Accident Summary Nr: 201031820 - Employee injured in fall when structure collapses

Accident Summary Nr: 201031820 -- Report ID: 0950635 -- Event Date: 01/06/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
12030129601/15/199937210The Boeing Company

Abstract: At approximately 12:35 p.m. on June 6, 1999, Employee #1, a welder, and a coworker were dismantling and wrecking a large, 15 ft by 30 ft by 14 ft high, MD11 aircraft assembly jig item #76-1, the MD-11 Combi-tool, that had earlier been brought over from building #3 and was lying in the open space outside of building #15. The assembly jig was comprised of miscellaneous structural steel. The workers' objective was to use an oxyacetylene torch to cut the whole steel structure into smaller segments and to put those into bins to be hauled away. Employee #1 allegedly cut partially through the bottom support brace and then cut two roof-level 4 in. square metal braces (or arms). When the two top supports were cut through, the weight load on the bottom support caused it to snap off and the whole arm fell forward. It struck Employee #1, who was still at the uppermost platform of the rolling ladder he was using to access the top the structure, and he fell 14 ft to the ground. He sustained severe head trauma and remained unconscious for approximately 1 minute. When he came to his senses, he was not unclear as to where he was or what had happened. He was taken to Long Beach (CA) Memorial Medical Center by paramedics, where he was diagnosed as having a concussion and hemorrhaging, and possible hip, pelvis, and elbow fractures. Coworkers later indicated that the dismantling job was not discussed in any detail before it was begun. It was left to the jig/ fixture person to communicate to Employee #1 what job was to be done that day, and the details of how it would be done, including any safety measure, was left to those two crew members. Normally for this type of job, support was provided by a fork lift, but apparently in this case no lift truck was available on that day. There was no written evidence to support that prior to the dismantling work, a survey was made by a qualified person about the possibility of an unplanned collapse of any portion of the structure. During the demolition/dismantling, continuous inspections were not made to detect hazards resulting from weakened or loosened material. The men were allowed to work under hazardous conditions without appropriate shoring or bracing of the structure under demolition.

Keywords: HEAD, DEMOLITION, COLLAPSE, WORK RULES, WELDER, FALL, FALL PROTECTION, BRACING, ELEVATED WORK PLAT, CUTTING AND BURNING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120301296 Hospitalized injury Other Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close