Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200920072 - Employee Killed When Struck By Backing Dump Truck

Accident: 200920072 -- Report ID: 0355114 -- Event Date: 05/20/1998
InspectionOpen DateSICEstablishment Name
12547111005/21/19981611General Excavation Inc.
Employee #1 was walking in the middle of a two-lane roadway under construction while a coworker was operating an off-road dump truck, compacting the soil. The truck was backing up when he was struck by its right rear tires. Employee #1 was killed. The driver did not see him and the truck's reverse signal alarm was not working at the time of the accident.
Keywords: back-up alarm, highway, signalman, construction, earthmoving equip, truck, dump truck, backing up
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street Maintenance or repair $500,000 to $1,000,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 125471110 Fatality Fracture Operating engineers FallDist:
FallHt:
Cause: Backfilling and compacting
FatCause: Crushed/run-over of non-operator by operating cons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close