Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200850949 - Employee Killed In Fall With Elevator Car

Accident: 200850949 -- Report ID: 0215000 -- Event Date: 03/26/1999
InspectionOpen DateSICEstablishment Name
10989442803/29/19991796C.E. Elevator Corp.
After changing over a hoist sheave on a sling-car, Employee #1 was to take the car from the roof to the cellar level to park it for the weekend. Just below the roof level, the 3/8 in. thick wire rope hoisting cable snapped and the car fell 11 stories to the sub-cellar pit. Employee #1 was killed. Subsequent investigation revealed that the wire rope had failed due to internal abrasion caused by imbedded glass wool particles. The car's safety brakes had not engaged because the governor connecting rod had not been installed.
Keywords: wire rope, broken cable, construction, equipment failure, fall, elevator, elevator shaft
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other building Alteration or rehabilitation $20,000,000 and over 9 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 109894428 Fatality Concussion Elevator installers and repairers FallDist:
FallHt:11
Cause: Elevator, escalator installation
FatCause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.