Accident Report Detail
Accident: 200831634 - Employee Is Sickened By Atmospheric Hazards In Trench
Accident: 200831634 -- Report ID: 0215600 -- Event Date: 09/14/2011 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
313432304 | 09/14/2011 | 1542 | Ruttura & Sons Construction Co., Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
313432312 | 09/14/2011 | 1711 | Metropolitan Sewer Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
313432296 | 09/14/2011 | 1542 | Turner Construction | ||||
At approximately 10:20 a.m. on September 14, 2011, Employee #1 was working in a trenching operation. The trench measured approximately 7 feet long by 7 feet wide by 15 feet deep. Employee #1 entered the trench and set up a core drill when he began to feel nauseous and dizzy. Employee #1 was equipped with a carbon monoxide and natural gas detector, however, no alarms sounded. Employee #1 climbed out of the trench and emergency services were called. Employee #1 was transported to a local hospital. The local Fire Department conducted atmospheric testing inside the trench at approximately 11:30 a.m., and received the following readings: Sulfur Dioxide (S02) 16.3ppm; Lower Explosive Limit 86% ; Oxygen (O2) Good; Hydrogen Sulfide (H2S) 9.4ppm; Carbon Monoxide (CO) 3ppm; ConEd Natural Gas 0; Volatile Organic Compounds (VOCs) 2,000ppm. Prior to entering the trench, Employee #1 spilled gasoline on his pants and boots while filling a generator. | |||||||
Keywords:
air monitoring, air contamination, dizziness, confined space, idlh, trench, nausea
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Other building | New project or new addition | $20,000,000 and over | 5 | 50 | |||