Accident: 200758720 - Employee Is Killed When Steel Column Falls

Accident: 200758720 -- Report ID: 0522500 -- Event Date: 10/07/2008
InspectionOpen DateSICEstablishment Name
31183845210/07/20081791Watertown Steel, Inc.
At approximately 12:30 p.m. on October 7, 2008, An employee was working as a ground man and was assisted by a coworker, also a ground man, where a steel column was being rigged on the ground and was to be hoisted and set in place on a concrete foundation. A rubber tired, Grove RT 745 Crane was being used to assist in the rigging process. A lifting mechanism that consisted of a choker, shackle, ropes and a cotter pin was being used. Based on the task at hand, the ground man would have attached the hinge pin through the shackle and then through the column splice lug hole and back through the other side of the shackle hole. A cotter pin would then be placed through the end tip of the hinge pin. A nylon rope would also be attached to the handle side of the hinge pin. Another nylon rope would be connected to the cotter pin so that when the steel column was erected, the rope would be pulled, the cotter pin would fall out and then the rope connected to the hinge pin would be pulled and that portion of the rigging apparatus would fall to the ground. The investigation revealed that during the initial set up, the cotter pin was placed down side up; so if the rope is pulled, the pin would not pop out. The coworker signaled the crane operator to begin the lift. As the column was being raised, the ground man noticed the inverted cotter pin and motioned the crane operator to stop. At that time, the ground man adjusted the cotter pin and motioned the crane operator to continue the lift. The rigging connection released from the column shortly after the column was hoisted to about a 45 degree angle. The mechanism had been placed under and not through the splice lug hole. The employee was killed when a 44.2 foot steel column, weighing about 2,300 lbs fell on him. The coworker stated that he did not notice that the rigging connection was not connected through the splice lug hole on the steel column. There was no work rule in place to address specific rigging procedures when erection operations involved rigging steel columns and beams hoisting said items. Also, there was no documentation that employees who performed rigging work were trained on implementing safe rigging connections when steel columns were being hoisted and set in place. The weather at the time of the accident was clear and sunny with no precipitation.
Keywords: hoisting mechanism, steel column, overhead crane, fall, struck by, falling object, crane
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building New project or new addition $5,000,000 to $20,000,000 4 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 311838452 Fatality Other Structural metal workers FallDist:
FallHt:
Cause: Erecting structural steel
FatCause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.