Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200742302 - Employee Is Crushed By Crane Boom And Later Dies

Accident: 200742302 -- Report ID: 0213100 -- Event Date: 11/27/2007
InspectionOpen DateSICEstablishment Name
31052395611/28/20077538Riverside Travel Plaza
At approximately 2:00 p.m. on November 27, 2007, Employee #1, a mechanic at a truck repair shop, was conducting preventive maintenance work on a HIAB crane (Model Number D2006, Serial Number 8220216) with an articulating knuckle boom mounted behind the cab of a flatbed truck. Employee #1 was not trained and certified to work on this type of crane. Employee #1 had raised the boom approximately two feet then unscrewed the valves that control the hydraulic boom. Employee #1 then climbed onto the truck behind the boom to continue working on another valve. By unseating the face plate on the valve the safety relief valve built up so much pressure that it blew causing the boom to fall and pin Employee #1 underneath the boom. Employee # 1 sustained trauma to the chest. Employee #1 was pulled out and transported to a local hospital where he died.
Keywords: asphyxiated, crane boom, hydraulic fluid, crushed, hydraulic crane
Employee # Inspection Age Sex Degree Nature Occupation
1 310523956 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close