Accident Report Detail
Accident Summary Nr: 200672962 - Employee killed in fall from communications tower
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 303185649 | 09/29/2000 | 7379 | 0 | Lineshark Communications |
Abstract: Employee #1, of Lineshark Communications, Inc., climbed a 198 ft tall communications tower to perform maintenance on the company's wireless internet transmitter, located at a height of approximately 70 ft. He was descending to the 40 ft level to rest when he fell to the ground. Employee #1 died as a result of head and chest trauma. He attempted to use a lanyard and belt, but they apparently would not reach around the tower at the height where the antenna was located.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 303185649 | Fatality | Bruise/Contus/Abras | Electrical and electronic technicians |
Translate