Accident Summary Nr: 200640985 - Employee killed when crushed by falling overhead door
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 302381009 | 12/29/1998 | 2013 | 0 | Cj Nutracon, Inc |
Abstract: Employee #1 and coworkers were trying to free a 1,400 lb overhead door that had become stuck. He used a forklift to raise the two coworkers to the door motor and controls and then dismounted to watch from the floor. Employee #1 was standing directly under the door when it broke free and dropped. He was crushed under the heavy door, and was killed. The door had not been blocked or braced.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 302381009 | Fatality | Other | Occupation not reported |