Accident Report Detail
Accident Summary Nr: 200611655 - Employee Killed When Run over by Dump Truck
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 306946096 | 04/30/2004 | 1611 | 237310 | James S. Piscopo, General Contractor, Inc. |
Abstract: At approximately 3:05 p.m. on Friday, April 30, 2004, Employee #1 was working as a spotter for a dump truck operator driving a Mack 10-wheel dump truck on a construction site. As the dump truck operator was backing up his truck, he stopped to allow two teenagers too cross the street behind the truck. When the dump truck operator noticed it was clear he proceeded to the back up. Employee #1 was directly behind the truck; and was struck and killed
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Highway, road, street | New project or new addition | $1,000,000 to $5,000,000 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 306946096 | Fatality | Other | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Backfilling and compacting Fatality Cause: Crushed/run-over/trapped of operator by operating |
Translate