Accident Summary Nr: 200601508 - Three employees drown when concrete form collapses into lake

Accident Summary Nr: 200601508 -- Report ID: 0625400 -- Event Date: 08/09/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30341597008/09/200016290M W Builders, Inc.

Abstract: Employees #1 through #3 were supervising the pouring of concrete into a steel mold for the construction of a 72 in. diameter column intended to support a 24 in. pipe from a pumping station on Stillhouse Hollow Lake, near Belton, TX. All three were tied off to the top of the form. Suddenly, there was a loud "pop" as the bottom of the 50 ft tall form blew out. The force knocked the form off the caisson, which was approximately 8 ft above the surface of the lake. Bolts holding the two parts of the form together sheared and the form fell over into the lake, taking all three workers with it. Employees #1 through #3 died of asphyxia by drowning. Employee #1's body was recovered within a few hours; the bodies of Employees #2 and #3 were found by divers after the form was lifted up onto a barge. All of the concrete mix had run out into the lake during and after the accident. The pour had taken about two hours but the concrete mix in the bottom of the form was like soup, suggesting that too much plasticizer had been added at the batch plant.

Keywords: CONCRETE FORM WORK, COLLAPSE, CONSTRUCTION, FALL, DROWN, CONCRETE, OVERTURN, WATER
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction New project or new addition $20,000,000 and over 60 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303415970 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erection of coffer dams, caissons
Fatality Cause: Drown, non-lethal fall
2 303415970 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erection of coffer dams, caissons
Fatality Cause: Drown, non-lethal fall
3 303415970 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erection of coffer dams, caissons
Fatality Cause: Drown, non-lethal fall

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.