Accident Summary Nr: 200556421 - Employee Dies after Strike by Pipe

Accident Summary Nr: 200556421 -- Report ID: 0625700 -- Event Date: 04/12/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31477007404/12/20111629237990Great Southern Dredging, Inc.

Abstract: On April 12, 2011, an employee was struck by a pipe that had the intake part of a waster pump attached. The employee was working with a coworker while another observed at the side. The crew was installing a new pump to an existing pumping station. During the connection of the intake tubing of the water pump with the tubing that had the pump, the crew was using a flange & stainless steel bolts to get both parts together. There was a gap to close the tubing with the flange and a fourth employee operating the excavator was bringing down the pipe carrying the intake with the bucket. At this time, the coworker was standing on top of the tubing that had the pump which was on the ground to give instructions to the operator. The employee was at the coworker's right hand connecting the bolts whose holes were already matching. The coworker told the operator to bring the bucket down to loosen the slings holding the intake tubing to relocate them to close the opening and finish the connection. While this was happening, the intake tubing flipped and struck the employee and coworker, sending both to the hospital. The coworker was later released with minor injuries, but the employee died.

Keywords: STUCK, BOLT, EXCAVATOR, PIPE, WATER PIPE, PUMP
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Alteration or rehabilitation $1,000,000 to $5,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314770074 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.