InspectionOpen DateSICEstablishment Name
30038687706/23/19991791Alpha Steel Erectors, Inc.
Employee #1 and a coworker were setting steel roof trusses and connecting the bridging while another coworker was in an aerial lift. When Employee #1 and his coworker finished their work, they climbed on top of the truss and began to walk along the truss flange. The aerial lift was being lowered when it struck the truss and caused it to vibrate. Both men lost their balance and fell, grabbing onto the truss. Employee #1 lost his grip and fell approximately 38 ft; he was killed. The coworker was able to hold on until he was rescued.
Keywords: clearance, iron worker, work rules, struck against, vibrations, fall, fall protection, walking on beam, aerial lift, unstable position
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building New project or new addition $5,000,000 to $20,000,000 1 38 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 300386877 Fatality Fracture Occupation not reported FallDist:
FallHt:45
Cause: Erecting structural steel
FatCause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.