Accident Report Detail
Accident Summary Nr: 200460830 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 302923149 | 08/24/2000 | 1794 | 0 | Cameo Enterprises Incorporated |
Abstract: Some employees were installing ductile iron pipe. Two of the employees were holding and guiding the pipe as an excavator moved it into position. The excavator contacted a 2400-volt overhead power line. Both employees received electric shocks, and one of them lost consciousness. A passing emergency medical services team received the emergency call and provided medical assistance. The team used a defibrillator and revived the unconscious worker, who was hospitalized for his injuries.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Sewer/water treatment plant | New project or new addition | Under $50,000 | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 302923149 | Non Hospitalized injury | Electric Shock | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Trenching, installing pipe Fatality Cause: Electrocution by equipment contacting wire |
||
| 2 | 302923149 | Hospitalized injury | Electric Shock | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Trenching, installing pipe Fatality Cause: Electrocution by equipment contacting wire |
Translate