Accident Summary Nr: 200371284 - Electric Shock - Contact with Overhead Line thru Boom

Accident Summary Nr: 200371284 -- Report ID: 0454510 -- Event Date: 08/25/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30243826208/26/200017710Carolina Concrete Pumping Inc.

Abstract: An employee was delivering concrete to a house under construction. He stopped his concrete pumping truck and got out. Standing on the ground, he was using a remote control device to move the boom. The boom contacted an overhead power line, and the employee was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CONCRETE TRUCK, ELECTROCUTED, E C
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $50,000 to $250,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302438262 Fatality Electric Shock Miscellaneous material moving equipment operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.