Accident Report Detail
Accident Summary Nr: 200356970 - Employee Is Struck and Killed by Water Tank Being Demolished
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 311934244 | 05/08/2008 | 1795 | 238910 | D. H. Griffin Wrecking Company, Inc. |
Abstract: On May 7, 2008, Employees #1 and three coworkers were tasked to dismantle an outdated water tank with handheld demolition equipment such as a cutting torch. During demolition, the employees worked on the second level and the supervisor in charge worked on the lower level removing debris. Employees #1 and three coworkers had approximately 75 percent of the tank cut apart prior to lunch. After lunch Employee #1 was told by the other employees not to cut anymore of the tank until a chain hoist was made available. Employee #1 disregarded the other employees and cut the approximate 700 pound section of steel, which fell on him, causing fatal fractures.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Manufacturing plant | Demolition | $50,000 to $250,000 | 2 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311934244 | Fatality | Fracture | Occupation not reported |