Accident Summary Nr: 200352185 - Demolition Employee Killed When Crushed by Load

Accident Summary Nr: 200352185 -- Report ID: 0453710 -- Event Date: 11/02/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30474410511/02/200117950D. H. Griffin Wrecking Company,Inc.

Abstract: On November 2, 2001, Employee #1 and coworkers were in process of lifting a 44,000 pound concrete slab that had been part of a bridge that was being demolished. The slab was being lifted by a crane while Employee #1 and another worker were underneath the slab, on a barge, cutting rebar and concrete with an oxygen assisted magnesium lance. The load had been lifted several times to break it loose from the pilings underneath the bridge. When the concrete slab was lowered back into its position on the pilings, slack was created in the wire rope basket hitch/sling, which was not noticed by the signalman or workers underneath the slab. At the same time, Employee #1 positioned his head and body under the load to cut the last piece of rebar and concrete. Due to the slack in the wire rope hitch/sling, after the rebar and concrete were cut, the load broke loose and dropped/rolled in the sling causing the concrete slab to strike, pin and crush Employee #1's head. When other workers heard the slab "pop and bang" and noticed no response from the location of Employee #1, the crane signalman gave signal for the crane operator to lift the load. When the load was lifted, Employee #1's body fell into the river, and was later retrieved by coworkers. Coworkers also called 911

Keywords: CONCRETE SLAB, FRACTURE, HEAD, DEMOLITION, CRUSHED, STRUCK BY, FALLING OBJECT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge Demolition $5,000,000 to $20,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304744105 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.