Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200350460 - Two Employees Killed In Fall From Moving Pickup Truck

Accident: 200350460 -- Report ID: 0453710 -- Event Date: 07/29/1997
InspectionOpen DateSICEstablishment Name
12531308008/04/19975159Teddy Leon Barnhill
Employees #1 and #2 were riding in the back of a pickup truck that was traveling at highway speed when they fell out. Both employees were killed.
Keywords: highway, vehicle, work rules, riding on equipment, truck, fall, pickup truck, motor vehicle
Employee # Inspection Age Sex Degree Nature Occupation
1 125313080 Fatality Fracture Occupation not reported
2 125313080 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close