Accident Summary Nr: 200330918 - Employee Killed In Fall From Broadcast Tower

Accident Summary Nr: 200330918 -- Report ID: 0830300 -- Event Date: 04/02/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30420339104/03/200216230Tim'S Tower Service, Inc.

Abstract: Employee #1 was working on a project that consisted of structurally upgrading an 1199-ft broadcasting tower. Employee #1 and a coworker were working on the tower. The anchorage point where Employee #1 was tied off released and Employee #1 fell approximately 75 ft. First aid and basic life support was administered by coworkers, but Employee #1 was pronounced dead at the accident scene.

Keywords: ANCHOR, COMMUNICATION TOWER, EQUIPMENT FAILURE, FALL, FALL PROTECTION, TIE-OFF, TOWER
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator Alteration or rehabilitation $500,000 to $1,000,000 1199 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304203391 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 75 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.