Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200271658 - Employee Amputates Four Fingers In Press Brake

Accident: 200271658 -- Report ID: 0524500 -- Event Date: 08/17/2006
InspectionOpen DateSICEstablishment Name
30857354208/22/20062542Pride Metals, L.L.C.
At approximately 5:15 a.m. on August 17, 2006, Employee #1 was using a Cincinnati press brake, Model Number 2323770, Serial Number 2357194, to put bends in 72-inch long, 16-gauge sheet metal to make locker doors. A door apparently became stuck on the press brake and, when the employee went to knock it free, the door started to slide out of the back of the press. As the employee reached into the point of operation of the press, his foot pressed on the foot pedal, activating the press brake. The press brake came down on the employee's right hand, crushing and amputating four fingers. He was hospitalized with his injuries. Further investigation revealed that the employee was operating the press brake without utilizing the supplied restraints.
Keywords: amputated, sheet metal, press brake, finger, stuck, foot control, machine operator, lockout, point of operation, restraining device
Employee # Inspection Age Sex Degree Nature Occupation
1 308573542 Hospitalized injury Amputation Fabricating machine operators, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close