Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200262822 - Employee Is Killed By Explosion

Accident: 200262822 -- Report ID: 0627100 -- Event Date: 05/16/2006
InspectionOpen DateSICEstablishment Name
30994645705/16/20062075Riceland Foods
Employee #1 was working in the hydrogenation area when he removed the lid from Converter Number 1 and placed it on the ground next to the approximately 25-in.-diameter opening to the converter. Employee #1 then removed the gasket from around the lid and used a wire-brush grinder to remove the silicone that had sealed the gasket to the lid. Converter Number 1 contained a mixture of vegetable oil and hydrogen. While Employee #1 was grinding the lid, sparks mixed with the hydrogen and exploded. Employee #1 was thrown approximately 7 ft into the air and onto some overhead pipes. Employee #1's right arm was severed and he was killed.
Keywords: grinder, severed, hydrogen, struck against, hot cooking oil, explosion, pipe, spark, arm, hand tool
Employee # Inspection Age Sex Degree Nature Occupation
1 309946457 Fatality Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close